2 Door Elevator Autocad
Free CAD and BIM blocks library - content for AutoCAD, AutoCAD LT, Revit, Inventor, Fusion 360 and other 2D and 3D CAD applications by Autodesk. CAD blocks and files can be downloaded in the formats DWG, RFA, IPT, F3D. You can exchange useful blocks and symbols with other CAD and BIM users. See popular blocks and top brands. Elevators dwg, free download, vast choice of file dwg for all the necessities of the planner. Architectural details, in this category you can find the most popular CAD architectural blocks and AutoCAD drawings for your work!
- 2 Door Elevator Autocad Blocks
- 2 Door Elevator Autocad Download
- 2 Door Elevator Autocad Software
- 2 Door Elevator Autocad Xforce
Hoistway Blocks
Click images for full view, download full drawings via links below images.
750lb. 36×48
950lb. 40×54
Inline openings. Left striking door with the equipment located on the right.
pdf / dwg
Inline openings. Left striking door with the equipment located on the left.
pdf / dwg
Inline openings. Left striking door with the equipment located opposite the opening.
pdf / dwg
Inline openings. Right striking door with the equipment located on the left.
pdf / dwg
Inline openings. Right striking door with the equipment located on the right.
pdf / dwg
2 Door Elevator Autocad Blocks
Inline openings. Right striking door with the equipment located opposite the opening.
pdf / dwg
Front & Rear Openings (walk-through). Front opening strikes to the left / rear opening strikes to the right with the equipment located on the right.
pdf / dwg
Front & Rear Openings (walk-through). Front & rear opening strike to the left with the equipment located on the right.
pdf / dwg
Front & Rear Openings (walk-through). Front opening strikes to the left / rear opening strikes to the right with the equipment located on the left.
pdf / dwg
Front & Rear Openings (walk-through). Front & rear openings strike to the right with the equipment located on the left.
pdf / dwg
Front & Rear Openings (walk-through). Front opening strikes to the right / rear opening strikes to the left with the equipment located on the left.
pdf / dwg
Front & Rear Openings (walk-through). Front & rear openings strike to the left with the equipment located on the left.
pdf / dwg
Front & Rear Openings (walk-through). Front opening strikes to the right / rear opening strikes to the left with the equipment located on the right.
pdf / dwg
Front & Rear Openings (walk-through). Front & rear openings strike to the right / rear opening strikes to the right with the equipment located on the right.
pdf / dwg
Front & Side Openings (90-degree). Front & side openings strike to the left with the equipment located on the right.
pdf / dwg
Front & Side Openings (90-degree). Front opening strikes to the left / side opening strikes to the right with the equipment located on the right.
pdf / dwg
2 Door Elevator Autocad Download
Front & Side Openings (90-degree). Front opening strikes to the right / side opening strikes to the left with the equipment located on the right.
pdf / dwg
Front & Side Openings (90-degree). Front & side openings strike to the right with the equipment located on the right.
2 Door Elevator Autocad Software
pdf / dwg
Front & Side Openings (90-degree). Front opening strikes to the right / side opening strikes to the right with the equipment located on the left.
pdf / dwg
Front & Side Openings (90-degree). Front opening strikes to the right / side opening strikes to the left with the equipment located on the left.
pdf / dwg
2 Door Elevator Autocad Xforce
Front & Side Openings (90-degree). Front opening strikes to the left / side opening strikes to the right with the equipment located on the left.
pdf / dwg
Front & Side Openings (90-degree). Front & side openings strike to the left with the equipment located on the left.
pdf / dwg
Other Drawings
3-Stop Elevation
pdf / dwg
5-Stop Elevation
pdf / dwg
6-Stop Elevation
pdf / dwg
Rail Brackets
pdf / dwg
**Drawings in AutoCAD format are offered as an added convenience to architects, builders and designers. Do not under any circumstances modify the dimensions within these drawings without consulting the factory. These drawings, and the Custom Elevator logo are copyrighted by Custom Elevator Manufacturing Company Incorporated.
The design utilizes dual two stage telescopic hydraulic jacks, located on each side of the platform and installed directly on the pit floor.
Advantages:
- Jack hole is not required. Eliminating the cost of drilling and the risk of ground contamination from oil leak.
- Offered in both low and high capacity elevators.
- Accommodates front and rear opening configurations.
- Accommodates travel up to approximately 26’-0”.
Disadvantages:
- May require a larger hoistway width to accommodate jacks mounted on either side of the platform.
- Additional service concerns due to jack synchronization and AutoSync circuit
- Side openings are not an option.
- Material cost is typically higher when compared to an in-ground application.
Passenger Dual Holeless Two Stage Hydraulic – Front Open Only
Type | Capacity (lbs) | Hoistway Width x Depth | Platform Width x Depth | Inside Cab Width x Depth | Door Type | Door Width | AutoCAD | |
Passenger | ||||||||
2000 | 7′-4″ x 5′-10″ | 6′-0″ x 5′-1″ | 5′-8″ x 4′-3″ | Single Speed | 3′-0″ | .dwg | ||
2500 | 8′-4″ x 5′-10″ | 7′-0″ x 5′-1″ | 6′-8″ x 4′-3″ | Single Speed | 3′-6″ | .dwg | ||
2500 | 8′-4″ x 5′-10″ | 7′-0″ x 5′-1″ | 6′-8″ x 4′-3″ | Center Open | 3′-6″ | .dwg | ||
3000 | 8′-4″ x 6′-3″ | 7′-0″ x 5′-6″ | 6′-8″ x 4′-8″ | Single Speed | 3′-6″ | .dwg | ||
3000 | 8′-4″ x 6′-3″ | 7′-0″ x 5′-6″ | 6′-8″ x 4′-8″ | Center Open | 3′-6″ | .dwg | ||
3500 | 8′-4″ x 6′-11″ | 7′-0″ x 6′-2″ | 6′-8″ x 5′-4″ | Single Speed | 3′-6″ | .dwg | ||
3500 | 8′-4″ x 6′-11″ | 7′-0″ x 6′-2″ | 6′-8″ x 5′-4″ | Center Open | 3′-6″ | .dwg | ||
4000 | 9′-8″ x 6′-11″ | 8′-0″ x 6′-2″ | 7′-8″ x 5′-4″ | Single Speed | 4′-0″ | .dwg | ||
4000 | 9′-8″ x 6′-11″ | 8′-0″ x 6′-2″ | 7′-8″ x 5′-4″ | Center Open | 4′-0″ | .dwg | ||
Hospital | ||||||||
4000 | 7′-8″ x 9′-6″ | 6′-0″ x 8′-8″ | 5′-8″ x 7′-8 1/2″ | Two Speed | 4′-0″ | .dwg | ||
4500 | 7′-8″ x 9′-11″ | 6′-0″ x 9′-1″ | 5′-8″ x 8′-1 1/2″ | Two Speed | 4′-0″ | .dwg | ||
5000 | 8′-3″ x 10′-5″ | 6′-0″ x 9′-7″ | 5′-8″ x 8′-7 1/2″ | Two Speed | 4′-6″ | .dwg |
Passenger Dual Holeless Two Stage Hydraulic – Front & Rear Open
Type | Capacity (lbs) | Hoistway Width x Depth | Platform Width x Depth | Inside Cab Width x Depth | Door Type | Door Width | AutoCAD | |
Passenger | ||||||||
2000 | 7′-4″ x 6′-9 1/2″ | 6′-0″ x 5′-9″ | 5′-8″ x 4′-4 3/4″ | Single Speed | 3′-0″ | .dwg | ||
2500 | 8′-4″ x 6′-9 1/2″ | 7′-0″ x 5′-9″ | 6′-8″ x 4′-4 3/4″ | Single Speed | 3′-6″ | .dwg | ||
2500 | 8′-4″ x 6′-9 1/2″ | 7′-0″ x 5′-9″ | 6′-8″ x 4′-4 3/4″ | Center Open | 3′-6″ | .dwg | ||
3000 | 8′-4″ x 7′-1 1/2″ | 7′-0″ x 6′-1″ | 6′-8″ x 4′-8 3/4″ | Single Speed | 3′-6″ | .dwg | ||
3000 | 8′-4″ x 7′-1 1/2″ | 7′-0″ x 6′-1″ | 6′-8″ x 4′-8 3/4″ | Center Open | 3′-6″ | .dwg | ||
3500 | 8′-6″ x 7′-9 1/2″ | 7′-0″ x 6′-9″ | 6′-8″ x 5′-4 3/4″ | Single Speed | 3′-6″ | .dwg | ||
3500 Stag. Open. | 8′-6″ x 7′-9 1/2″ | 7′-0″ x 6′-9″ | 6′-8″ x 5′-4 3/4″ | Side Slide | 3′-6″ | .dwg | ||
3500 | 8′-6″ x 7′-9 1/2″ | 7′-0″ x 6′-9″ | 6′-8″ x 5′-4 3/4″ | Center Open | 3′-6″ | .dwg | ||
4000 | 9′-8″ x 7′-9 1/2″ | 8′-0″ x 6′-9″ | 7′-8″ x 5′-4 3/4″ | Single Speed | 4′-0″ | .dwg | ||
4000 | 9′-8″ x 7′-9 1/2″ | 8′-0″ x 6′-9″ | 7′-8″ x 5′-4 3/4″ | Center Open | 4′-0″ | .dwg | ||
Hospital | ||||||||
4000 | 7′-8″ x 10′-7 1/2″ | 6′-0″ x 9′-4″ | 5′-8″ x 7′-8 3/4″ | Two Speed | 4′-0″ | .dwg | ||
4500 | 7′-8″ x 11′-0 1/2″ | 6′-0″ x 9′-9″ | 5′-8″ x 8′-1 3/4″ | Two Speed | 4′-0″ | .dwg | ||
5000 | 8′-3″ x 11′-6 1/2″ | 6′-0″ x 10′-3″ | 5′-8″ x 8′-7 3/4″ | Two Speed | 4′-6″ | .dwg |
Additional Specs
Pit Depth = 4′-0″
Standard Cab Height = 8′-0″
Speed available to 150 FPM
Consult factory for overhead requirements
Notes for Dual Holeless
- 2000-lb. car complies with NEII recommendations for car to accommodate wheelchair.
- 2500-lb. and larger cars comply with NEII recommendations for car to accommodatestretcher when equipped with single slide doors.
- 3500-lb. and larger cars comply with NEII recommendations for car to accommodatestretcher when equipped with single slide doors.
This information is intended for preliminary planning. We have attempted to include the basic data that you will require in your planning efforts. For details about specific or custom installations please contact your local Canton Elevator representative, or contact us directly.pen.